Key Features

  • Pre-configured applications selectable from a single parameter (Ps)
  • Universal inputs: wide range of selectable probe types
  • Direct compressor control through a high inrush-current relay
  • Zero-crossing TRIAC output for EC fan switching
  • Auxiliary output and independent relay
  • Embedded local Wi-Fi for fast commissioning and HACCP management
  • Extended power-supply range
  • RS485 serial port
  • Suitable for flammable refrigerants (A2L/A3) thanks to sealed relays

Product range

Technical Data
Inputs Sensor type T1,T2 NTC2k, NTC10k Beta1, NTC10k Beta2, PTC
T3/DI1, T4/DI2 NTC10k Beta1, NTC10k Beta2, PT1000, Digital Input
T5/DI3 NTC10k Beta1, NTC10k Beta2, 0-1V, Digital Input
Outputs OUT1 Compressor 16A FLA / 96A LRA @240Vac
OUT2 Auxiliary / defrost 7A resistive @ 240Vac
OUT3 Auxiliary loads 10A resistive @ 240Vac (Independent)
OUT4 Auxiliary / fan SSR 1A
Technical specifications Power supply 100÷240Vac ±10% 50÷60Hz 3W
Front protection IP54 (with gasket)
Buzzer Yes
Real Time Clock battery >10 years
Dimensions 77 x 35 x 90 mm
Panel-cutout 71 x 29 mm (WxH)
Connectivity WiFi CK5…: IEEE 8802.11ax 2.4 GHz Wi-Fi 6 (fully compatible with IEEE 802.11b/g/n protocol)
Environment conditions Operating temperature & humidity -10… +50°C; 15%… 80% rH
Conformity Marks CE
Use with flammable refrigerants A2L/A3 gases thanks to sealed relays (model depending)