Temperature probes
|
 |
| Technical Data |
 |
Pt100
SP1N..P-X Sensor type: Pt100 class “B” (DIN 43760), 100ohm @ 0°C Range: -40÷120°C Accuracy: ±0.3°C (0÷60°C) Sheath: Ø6x70mm; stainless steel Cable: 3 wires x 0.22mm2; -40÷120°C; PETE; points Protection: IP67
SPTO Sensor type: Pt100 class “B” (DIN43760), 100ohm @ 0°C Range: 0÷400°C Accuracy: ±0.3°C or ±0.5°C (in the worst case scenario) Response time: 10 seconds in water Sheath: Ø6x160mm; stainless steel AISI316 Cable: 3 wires x 0.24mm2; L=100cm, fiber glass, points Protection: IP65
Thermocouples
TJ.ECO Sensor type: J thermocouple Range: 0÷450°C Accuracy: ±2.5°C or ±0.75% (in the worst case scenario) Response time: 10 seconds in water Sheath: Ø6x160mm; stainless steel AISI316 Cable: 2 wires x 0.50mm2; L=300cm, fiber glass, points Protection: IP65
TK.ECO Sensor type: K thermocouple Range: 0÷600°C Accuracy: ±2.5°C or ±0.75% (in the worst case scenario) Response time: approx. 2 seconds in water Sheath: Ø4.5x160mm; INCONEL600 Cable: 2 wires x 0.24mm2; L=300cm, fiber glass, points Protection: IP65
|
|
 |
|
|
|